Categories of Cover Up

Cantega manufactures all of its covers using precise fit design technologies.  Our  cover-up products are designed to fit each unique piece of equipment from within 1/8th to 1/16th of an inch of accuracy. Because we image the equipment to be protected and manufacture our products based on those images, we don’t publish a catalogue.

We have over 700 moulds of equipment for which we have manufactured Greenjacket covers and we continue to receive new equipment types and configurations which add to the total number of moulds in inventory. The attached table lists the major categories of  Greenjacket covers and provides sample icon images of covers that are available.

Also listed are Reliaguard cover types. The Reliaguard line of covers will expand over time. Priority for expanding the Reliaguard line are based on volumes of covers in demand by our customers. Additional Reliaguard covers will be designed and made available at our customer’s request and based on volumes required.

1
Greenjacket Custom Designed
Cover-up Over 600 Product Designs

Applications: Able to Cover any type of substation or powerline equipment

See More

Description: Cantega Technologies uses Technology and Lineman Expertise to Design Covers for Electrical Utility Applications. We can prevent animal outages with Cantega’s precise-fit Greenjacket® product line. We focus on the precise design of covers to enable easy application.

Installation: De-energized or Energized installation using proprietary patent pending hot stick attachment tools

2
Reliaguard Precise Fit Commodity Cover-ups

Applications: Intended for volumes of covers for Powerline and substations

See More

Description: Using established imaging and design technologies, precise fit hot stickable covers are designed to prevent outages by delivering superior design features.

Installation: De-energized or Energized installation using proprietary patent pending hot stick attachment tools

33-23-13-43-3
Greenjacket Bushing Covers

Applications: Substations

See More
Description: Where varying sizes of bushings exist in a substation, Greenjacket can be made to the precise height and fit ensuring that insulator flights are not compromised and that gaps are eliminated

Installation: De-energized or Energized

 4
Reliaguard Hot Stickable Bushing Covers

Applications: Powerline

See More
Description: Designed for use with a shot gun hotstick to install on the powerline thus eliminating the need for rubber glove work application

Installation: De-energized or Energized

5-15-25
Greenjacket Bus and Flat Bar Covers

Applications: Substations

See More
Description: Available in a variety of sizes – offers bus coverage without the need for heat shrink wraping or taping

Installation: De-energized or Energized

66-1
Greenjacket CT Covers

Applications: Substations

See More
Description: Designed a precise fit to accommodate varying sizes of CT configurations

Installation: De-energized or Energized

7
Greenjacket Dive Arm Covers

Applications: Substations

See More
Description: Covers expensive equipment while allowing free movement of Drive Arm assemblies

Installation: De-energized or Energized

88-18-2
Greenjacket Expansion Joint Covers

Applications: Substations

See More
Description: Available in a variety of sizes to accommodate coverage of common perch points

Installation: De-energized or Energized

99-19-2
Greenjacket Insulator, Post Insulator Covers

Applications: Substation and Powerline

See More
Description: Precise fit and available in a variety of configurations

Installation: De-energized or Energized

10
Reliaguard Insulator, Post Insulator  Covers

Applications: Substation and Powerline

See More
Description: Designed for specific brands of insulators – intended for high volumes of standard size

Installation: De-energized or Energized

1111-111-2
Greenjacket Lightening Arrestor Covers

Applications: Substation and Powerline

See More
Description: Available in a variety of sizes for small or large volumes

Installation: De-energized or Energized

12
Reliaguard Lightening Arrestor Covers

Applications: Substation and Powerline

See More
Description: Intended for large volumes of similar size and types of arrestors

Installation: De-energized or Energized

1313-113-2
Greenjacket Switch Covers

Applications: Substation

See More
Description: Intended for small volumes of unique Cut Out Switch covers

Installation: De-energized or Energized

1414-114-2
Greenjacket Top Hat and Tea Cup Disks

Applications: Substation and Powerline

See More
Description: Intended to prevent animal climbing or wing span contact – solid and sloped to prevent nesting on top

Installation: De-energized or Energized

 1515-115-2
Greenjacket Terminator Covers

Applications: Substation

See More
Description: Designed a precise fit to accommodate varying sizes of termination configurations

Installation: De-energized or Energized

1616-116-2
Greenjacket Bus Plugs and Box Beam Hot Stickable Inserts

Applications: Substation

See More
Description: Designed to fit the ends of bus or box beam cavities where nesting is common and attracts larger predators – tool for end of hot stick provide with orders allowing maintenance crews to apply hot while conducting maintenance routines in the substation

Installation: De-energized or Energized

1717-117-2
Greenjacket Channel and Structure Covers

Applications: Substation

See More
Installation: De-energized or Energized
1818-118-2
Greenjacket Connector Covers

Applications: Substation

See More
Installation: De-energized or Energized
1919-119-2
Greenjacket PT VT Covers

Applications: Substation

See More
Installation: De-energized or Energized
20
Reliaguard Feeder Link Barrier

Applications: Substation

See More
Description: Perch deterrents designed with a slope so that nesting material can not collect on a flat surface.  Available for a variety of applications on flat surfaces

Installation: De-energized or Energized

2121-1
Greenjacket Breaker and Regulator Kits

Applications: Substation

See More
Description: Stockable Kits that allow field workers to grab and go with a kit of bushing covers designed for specific breaker types

Installation: De-energized or Energized

2222-122-3
Greenjacket Recloser Covers

Applications: Substation

See More
Installation: De-energized or Energized
2323-123-2
Greenjacket Sight Glass Covers

Applications: Substation

See More
Description: Designed for each type of sight glass to ensure that sight glass is visible while covering all energized risk points including cap on top of sight glass

Installation: De-energized or Energized

2424-1
Greenjacket Transformer Covers

Applications: Substation

See More
Description: Designed for each size of bushing with coverage to above the 1st insulator flight – precise fit to ensure there is no slippage

Installation: De-energized or Energized

25
Reliaguard Transformer Covers

Applications: Powerline

See More
Description: For pole-mounted transformers where large volumes of covers are required hot stickable

Installation: De-energized or Energized

There is no custom code to display.

© 2006 Cantega® Technologies Inc. Cantega® and Greenjacket® are registered trademarks of Cantega Technologies Inc.

Cantega Technologies Inc. | 100, 17866-106A Avenue | Edmonton, Alberta  Canada| T5S 1V3